GUIDE TO INSTALLATION AND OPERATION
RCP-100 | 7
Case 3 (figure 3.6)
Here an iControl APPLICATION SERVER is connected to the LAN. In this case, all RCP-100s must be
configured as CLIENTs, and the APP SERVER will function as the SERVER. An RCP-100 in CLIENT mode
will control Imaging and Densité cards through the APP SERVER via the ethernet connection.
Note: Any device can be controlled by a maximum of 8 RCP-100 CLIENTs
Figure 3.6 Installation of RCP-100s with an Application Server
In this set-up, the settings would be similar to these:
• the IP address of the AppServer is 10.2.5.10
• the IP address of RCP-100 #1 (client) is 10.2.5.20
• the IP address of RCP-100 #2 (client) is 10.2.5.21
Settings for RCP-100 #1 (client)
IPADDR: 10.2.5.20
SERVICE CONFIG – ICOM: OFF
DCOM: OFF
DSRV: OFF
DSRV IP: 10.2.5.10 (the IP address of the App. Server)
Settings for RCP-100 #2 (client)
IPADDR: 10.2.5.21
SERVICE CONFIG – ICOM: OFF
DCOM: OFF
DSRV: OFF
DSRV IP: 10.2.5.10 (the IP address of the App. Server)
Note: When an RCP-100 is configured as the client of an AppServer running iControl, the iControl Services
Gateway component must be started in the iControl Services Monitoring and Configuration tool. See the
iControl User’s Manual for detailed information on this setting.
The ethernet ports of the RCP-100 (client) devices must be connected to the same LAN subnet as the ETH0
port of the AppServer.