GUIDE TO INSTALLATION AND OPERATION
Kaleido-Solo | 43
Loudness chart (dual meter representation)
The color identifies the traces (center section) with their numeric values (left section).
Refer to EBU R128 or ATSC A/85 specification for more details.
Graphic representation of short term, integrated measurement and the target value. The time
scale is represented at the bottom of this section. Those traces can be independently shown or
hidden (see section 5.5.2). The “EBU Mode or A85 Mode” is displayed only when the
measurements are compliant to those specifications (see section 5.4.6).
Meter that represents the momentary measurement.
Loudness chart alarm
When the integrated value goes outside the upper and lower tolerance an alarm is triggered. A red frame will appear
around the loudness chart. You can trigger the GPI out with this alarm (see section 5.9).
Upper/Lower Alarm
Tolerances
ATSC A/85
ITU-r BS.1770-1
ATSC A/85
ITU-r BS.1770-2
Note that the alarm tolerances are not configurable.