GUIDE TO INSTALLATION AND OPERATION
42 | Kaleido-Solo
Position
Move all loudness charts to the desired position on the screen:
Top Left
Top Center
Top Right
Bottom Left
Bottom Center
Bottom Right
Center
Loudness chart (mono meter representation)
The color identifies the traces (center section) with their numeric values (top section).
Refer to EBU R128 or ATSC A/85 specification for more details.
S: Short term, since last reset.
I: Integrated, since last reset.
T: Target.
TPmax: Maximal true peak, since last reset.
LRA: Loudness range.
Mmax: Maximal Momentary, since last reset.
Shows if the alarm condition (see Loudness chart alarm) is triggered (RED) by the measure 1
and/or 2. Both charts are active at all time but only one can be displayed at a time.
Graphic representation of the short term, integrated measurement and the target value. The
time scale is represented at the bottom of this section. Those traces can be independently
shown or hidden (see section 5.5.2). The “EBU Mode or A85 Mode” is displayed only when the
measurements are compliant to those specifications (see section 5.4.6). Markers appear when
an audio loudness control reset is applied (see section 5.4.7). The integrated value for the
segment will appear next to the marker.
Meter that represents the momentary measurement.