GUIDE TO INSTALLATION AND OPERATION
8 | FLO-1601
4 Specifications
RF INPUT
Frequency Range 950Mhz – 2150MHz
Connector 75 Ohm “F” connector
Return loss > 10dB across the whole frequency range (950-2150MHz)
Input power range -60dBm to -20dBm
Maximum input level -20dBm
OUTPUTS
RF Monitoring Output
Frequency Range 950Mhz – 2150MHz
Connector 75 Ohm “F” connector
Return loss > 10dB across the whole frequency range (950-2150MHz)
Output Level same as input signal
Optical Output
Laser Distributed Feedback (DFB)
Optical Wavelength 1310nm
Connector SC/APC
Output Power +3dBm NOTE: This power level is sufficient to overload the optical
input of an FOL-1601 receiver. An optical attenuator
may be required at the FOL-1601 input for short-
haul circuits.
PHYSICAL AND POWER SPECIFICATIONS
Height: As specified by the DENSITÉ standard form factor
Length: As specified by the DENSITÉ standard form factor
Connection: Double rear connector panel
Consumption 10W typical