RCP-BR: Guide to Installation and Operation
Miranda Technologies Inc. Page 15
3 Using the RCP-BR panel
3.1 Turning on the unit
The RCP-BR unit is DC-powered and a DC power supply unit is supplied with
the RCP-BR that runs off of an AC mains supply.
To turn on the unit:
1. Ensure that the AC mains supply to the RCP-BR is off or not connected
for at least 10 seconds.
2. Then insert the DC power supply connector into the unit
3. Then apply AC mains to the power supply unit.
The LCD on the RCP-BR panel should initially be off; the LEDs on the bar at the
bottom of the unit should gradually change colour from left-to-right to indicate
the progress of the unit’s initialisation. Shortly after the progress bar has reached
the right hand side, the LCD display will turn on showing the channel selector
view.
Do not remove power while unit is booting.
3.2 Turning off the unit (Shutting down)
The RCP-BR must be shutdown.
The RCP-BR must not be directly turned off.
Do not remove power while the unit is shutting down.
The RCP-BR unit is normally shutdown via the System Panel screen. In some
cases, the user may wish to shut down from the small Control Window Dialog.
The procedure for both is described below:-